5.25.6 32-9* Development
Parameter 32-90 Debug Source
Table 1167: Parameter 32-90 Debug Source
32-90 Debug Source
Default value: [0] Controlcard
Parameter type: Option
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Controlcard
[1]
Option
5.26 Parameter Group 33-** MCO Adv. Settings
Parameters in this group are available when VLT® Motion Control Option MCO 305 is installed in the drive. For information about
the option, see the VLT® Motion Control Option MCO 305 Operating Instructions.
5.26.1 33-0* Home Motion
Parameter 33-00 Force HOME
Table 1168: Parameter 33-00 Force HOME
33-00 Force HOME
Default value: [0] Home not forced
Parameter type: Option
Setup: 2 setups
Conversion index: -
Data type: Uint8
Change during operation: True
Option
Name
Description
[0]*
Home not forced
[1]
Home forced
Parameter 33-01 Zero Point Offset from Home Pos.
Table 1169: Parameter 33-01 Zero Point Offset from Home Pos.
33-01 Zero Point Offset from Home Pos.
Default value: 0
Parameter type: Range, -1073741824 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Int32
Change during operation: True
Use this parameter to set an offset of 0 (home position) compared to the position after homing.
Parameter 33-02 Ramp for Home Motion
Table 1170: Parameter 33-02 Ramp for Home Motion
33-02 Ramp for Home Motion
Default value: 10
Parameter type: Range, -1 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Uint32
Change during operation: True
This parameter defines the ramp time (in ms) from standstill to the value set in
parameter 32-80 Maximum Allowed Velocity
.
AU275636650261en-000101 / 130R0334 | 601
Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide