Op-
tion
Name
Description
[16]
Mar. meas.
catch up
Continuous measurement of distance between master and follower marker. At every follower marker the
distance is measured to the latest master marker. The result of the measurement is updated in
parameter
18-24 Marker Pos. Offset
in position units as defined in
parameter group 17-0* Position Scaling
.
[17]
Mar. meas.
slow down
Continuous mesaurement of distance between master and follower marker. At every master marker the
distance is measured to the latest follower maker. The result of the measurement is updated in
parameter
18-24 Marker Po. Offset
in position units as defined in
parameter group 17-0* Position Scaling
.
[20]
CAM
Synchronizing according to the profile defined by
parameter 3-36 CAM Master Table
and
parameter 3-37
CAM Follower Table
.
[21]
CAM offset
Synchronizing according to the profile defined by
parameter 3-36 CAM Master Table
and
parameter 3-37
CAM Follower Table
with master offset defined in
parameter 3-26 Master Offset
.
Parameter 3-34 Marker Distance
Table 216: Parameter 3-34 Marker Distance
3-34 Marker Distance
Default value: 0 CustomReadoutUnit2 Parameter type: Range, 0 - 2147483647 CustomReadoutU-
nit2
Setup:
Conversion index: 0
Data type: Int32
Change during operation:
N O T I C E
This parameter is only available with software version 48.XX.
Enter the approximate distance between 2 markers. To measure the marker distance for follower or master marker, select the corre-
sponding marker measuring function in
parameter 3-33 Sync. Mode & Start Behavior
. Marker distance is in position units as defined in
parameter group 17-1* Position Scaling
. The value is converted to the position units of the follower using the master scale set in
parameter 3-22 Master Scale Numerator
and
parameter 3-23 Master Scale Denominator
. Configure the marker distance to utilize the
marker window function.
Parameter 3-35 Marker Window
Table 217: Parameter 3-35 Marker Window
3-35 Marker Window
Default value: 0 CustomReadoutUnit2
Parameter type: Range, 0 - par. 3-34 CustomReadoutUnit2
Setup:
Conversion index: 0
Data type: Int32
Change during operation:
N O T I C E
This parameter is only available with software version 48.XX.
Make sure to configure
parameter 3-34 Marker Distance
. The marker window function is only active when the marker distance is set.
Enter the window size around the expected marker position where the marker is accepted. The marker window is used for both
master and follower marker and the position units are as defined in
parameter group 17-7* Position Scaling
. Master position value is
converted to follower position units using the master scale set in
parameter 3-22 Master Scale Numerator
and
parameter 3-23 Master
Scale Denominator
.
AU275636650261en-000101 / 130R0334
140 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide