Option Name
Description
[37]
Analog Input X49/1
[38]
Analog Input X49/3
[39]
Analog Input X49/5
Parameter 3-16 Reference Resource 2
Table 200: Parameter 3-16 Reference Resource 2
3-16 Reference Resource 2
Default value: [20] Digital pot.meter
Parameter type: Option
Setup: All setups
Conversion index: –
Data type: Uint8
Change during operation: True
Select the reference input to be used for the 2
nd
reference signal.
Parameter 3-15 Resource Reference 1
,
parameter 3-16 Resource Refer-
ence 2
, and
parameter 3-17 Resource Reference 3
define up to 3 different reference signals. The sum of these reference signals defines
the actual reference. When
parameter 1-00 Configuration Mode
is set to
[9] Positioning
. Configure
parameter 3-16 Reference Resource 2
to select the source for target position.
N O T I C E
The options [3],[4],[5], [6], [12], [13], and [14] are only available with software version 48.XX.
Option Name
Description
[0]
No function
[1]
Analog Input 53
[2]
Analog Input 54
[3]
24V Encoder 32/33
Single signal generated from 24 V High Threshold Logic (HTL) encoder connected to terminals
32 and 33. Configure the 24 V encoder interface in
parameter group 5–7* 24 V Encoder Option
.
Program terminals 32/33 to
[0] No operation
.
[4]
MCB 102
This is only available for VLT® Encoder Option MCB 102. Configure the encoder interface in
pa-
rameter groups 17-0*, 17-1*, and 17-2*
.
[5]
MCB 103
This is only available for VLT® Resolver Option MCB 103. Configure the resolver interface in
pa-
rameter group 17-5* Resolver Interface
.
[6]
Virtual Master
Master signal for the drive which hosts the virtual master without an external connection. This
option is only active when option
[10] Synchronization
is selected in
parameter 1-00 Configura-
tion Mode
.
[7]
Frequency Input 29
N O T I C E
This option is only available in FC 302.
[8]
Frequency Input 33
[11]
Local Bus Reference
Reference from terminals 68 and 69.
[12]
Preset Reference
AU275636650261en-000101 / 130R0334