Option
Name
Description
[1]*
No action
[2]
Reference reversed
[3]
User units reserved
[4]
Uu and ref reversed
Parameter 32-11 User Unit Denominator
Table 1122: Parameter 32-11 User Unit Denominator
32-11 User Unit Denominator
Default value: 1
Parameter type: Range, 1 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Uint32
Change during operation: True
All target positions are made in user units and are converted to quad-counts internally. By selecting scaling units, it is possible to
work with any measurement unit (for example mm). This factor consists of a numerator and denominator.
Parameter 32-12 User Units Numerator
Table 1123: Parameter 32-12 User Units Numerator
32-12 User Units Numerator
Default value: 1
Parameter type: Range, 1 - 1073741823
Setup: 2 setups
Conversion index: 0
Data type: Uint32
Change during operation: True
All target positions are made in user units and are converted to quad-counts internally. By selecting scaling units, it is possible to
work with any measurement unit (for example mm). This factor consists of a numerator and denominator.
Parameter 32-13 Enc.2 Control
Table 1124: Parameter 32-13 Enc.2 Control
32-13 Enc.2 Control
Default value: [0] No soft changing
Parameter type: Option
Setup: 2 setups
Conversion Index: -
Data Type: Uint8
Change during operation: True
Enables bump-less changing of feedback encoder in software while running and setting position to 0 without loosing the actual
position.
Option
Name
Description
[0]*
No soft changing
[1]
Encoder soft changing enable
[2]
Soft zero setting enable
[3]
Encoder soft changing and soft zero enable
Parameter 32-14 Enc.2 Node ID
Table 1125: Parameter 32-14 Enc.2 Node ID
32-14 Enc.2 Node ID
Default value: 127
Parameter type: Range, 1 - 127
Setup: 2 setups
Conversion index: 0
Data type: Uint8
Change during operation: True