Parameter 0-31 Min Value of User-defined Readout
Table 22: Parameter 0-31 Min Value of User-defined Readout
0-31 Min Value of User-defined Readout
Default value: 0 CustomReadoutUnit Parameter type: Range, -999999.99 CustomReadoutUnit
- par. 0-32
Setup: All setups
Conversion index: -2
Data type: Int32
Change during operation: True
This parameter sets the minimum value of the custom-defined readout (occurs at 0 speed). Only possible to set different from 0
when selecting a linear unit in
parameter 0-30 Unit for User-defined Readout
. For quadratic and cubic units, the minimum value is 0.
Parameter 0-32 Max Value of User-defined Readout
Table 23: Parameter 0-32 Max Value of User-defined Readout
0-32 Max Value of User-defined Readout
Default value: 100 CustomReadoutUnit Parameter type: Range, par. 0-31 -999999.99 Custom-
ReadoutUnit
Setup: All setups
Conversion index: -2
Data type: Int32
Change during operation: True
This parameter sets the maximum value to be shown when the speed of the motor has reached the set value for
parameter 4-13
Motor Speed High Limit [RPM]
or
parameter 4-14 Motor Speed High Limit [Hz]
(depends on setting in
parameter 0-02 Motor Speed Unit
).
AU275636650261en-000101 / 130R0334
52 | Danfoss A/S © 2022.12
Parameter Descriptions
VLT AutomationDrive FC 301/302
Programming Guide