Parameter 12-81 HTTP Server
Table 654: Parameter 12-81 HTTP Server
12-81 HTTP Server
Default value: [0] Disabled
Parameter type: Option
Setup: 2 setups
Conversion index: –
Data type: Uint8
Change during operation: True
Enables/disables the built-in HTTP (web) server.
Option
Name
Description
[0]*
Disabled
[1]
Enabled
Parameter 12-82 SMTP Service
Table 655: Parameter 12-82 SMTP Service
12-82 SMTP Service
Default value: [0] Disabled
Parameter type: Option
Setup: 2 setups
Conversion index: –
Data type: Uint8
Change during operation: True
Enables/disables the built-in SMTP (e-mail) service on the option.
Option
Name
Description
[0]*
Disabled
[1]
Enabled
Parameter 12-83 SNMP Agent
Table 656: Parameter 12-83 SNMP Agent
12-83 SNMP Agent
Default value: [1] Enabled
Parameter type: Option
Setup: 2 setups
Conversion index: –
Data type: Uint8
Change during operation: True
Use this parameter to either enable or disable the SNMP agent.
Option
Name
Description
[0]
Disabled
[1]*
Enabled
Parameter 12-84 Address Conflict Detection
Table 657: Parameter 12-84 Address Conflict Detection
12-84 Address Conflict Detection
Default value: [1] Enabled
Parameter type: Option
Setup: 2 setups
Conversion index: –
Data type: Uint8
Change during operation: True
Use this parameter to detect and resolve IP address conflict.