Cisco ONS 15454 Procedure Guide, R5.0
October 2005
Chapter 22 DLPs A500 to A599
DLP-A526 Change Line and Threshold Settings for the DS3i-N-12 Cards
describes the values on the Provisioning > Elect Path Thresholds tabs for the DS3i-N-12
cards.
describes the values on the Provisioning > SONET Thresholds tabs for the DS3i-N-12 cards.
ES
Errored seconds
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
LOSS
Loss of signal seconds; number
of one-second intervals
containing one or more LOS
defects
Numeric. Can be set for 15-minute or one-day intervals.
Select the bullet and click the
Show Thresholds
button.
Table 22-2
Line Threshold Options for the DS3i-N-12 Cards (continued)
Parameter
Description
Options
Table 22-3
Electrical Path Options for the DS3i-N-12 Cards
Parameter
Description
Options
Port
(Display only.) Port number
1 to 12
CVP
Coding violations
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click the
Show Thresholds
button (DS3 Pbit: Near End only;
DS3 CPbit: Near and Far End).
ESP
Errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SESP
Severely errored seconds
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
SASP
Severely errored frame/alarm
indication signal–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
UASP
Unavailable seconds–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
AISSP
Alarm indication signal
seconds–path
Numeric. Can be set for 15-minute or one-day
intervals. Select the bullet and click
Show Thresholds
(DS3 Pbit: Near End only; DS3
CPbit: Near and Far End).
Содержание ONS 15454 Series
Страница 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 126: ...4 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 4 Turn Up Node NTP A256 Set Up SNMP ...
Страница 168: ...5 42 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 5 Turn Up Network NTP A172 Create a Logical Network Map ...
Страница 304: ...10 8 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 10 Change Node Settings NTP A87 Change SNMP Settings ...
Страница 410: ...16 4 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 16 Power Down the Node NTP A114 Power Down the Node ...
Страница 510: ...17 100 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 17 DLPs A1 to A99 DLP A99 Determine Available VLANs ...
Страница 746: ...20 102 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 20 DLPs A300 to A399 DLP A399 Install a UBIC H EIA ...
Страница 828: ...A 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...