18-52
Cisco ONS 15454 Procedure Guide, R5.0
March 2007
Chapter 18 DLPs A100 to A199
DLP-A171 Change Threshold Settings for OC-N Cards
ES
Errored seconds
Numeric. Can be set for 15-minute or
one-day intervals for Line, Section, or
Path (Near and Far End). Select the bullet
and click
Refresh
.
SES
Severely errored seconds
Numeric. Can be set for 15-minute or
one-day intervals for Line, Section, or
Path (Near and Far End). Select the bullet
and click
Refresh
.
SEFS
Severely errored framing seconds
Numeric. Can be set for 15-minute or
one-day intervals for Line, Section, or
Path (Near and Far End). Select the bullet
and click
Refresh
.
FC
Failure count
Numeric. Can be set for 15-minute or
one-day intervals for Line or Path (Near
and Far End). Select the bullet and click
Refresh
.
UAS
Unavailable seconds
Numeric. Can be set for 15-minute or
one-day intervals for Line or Path (Near
and Far End). Select the bullet and click
Refresh
.
PSC
Protection Switching Count (Line)
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
PSD
Protection Switch Duration (Line)
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
PSC-W
Protection Switching Count - Working line
BLSR is not supported on the OC-3 card;
therefore, the PSC-W, PSC-S, and PSC-R
PM parameters do not increment.
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
PSD-W
Protection Switching Duration - Working
line
BLSR is not supported on the OC-3 card;
therefore, the PSD-W, PSD-S, and PSD-R
PM parameters do not increment.
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
PSC-S
Protection Switching Duration - Span
BLSR is not supported on the OC-3 card;
therefore, the PSC-W, PSC-S, and PSC-R
PM parameters do not increment.
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
PSD-S
Protection Switching Duration - Span
BLSR is not supported on the OC-3 card;
therefore, the PSD-W, PSD-S, and PSD-R
PM parameters do not increment.
Numeric. Can be set for 15-minute or
one-day intervals for Line (Near and Far
End). Select the bullet and click
Refresh
.
Table 18-22
OC-N Threshold Options (continued)
Parameter
Description
Options
Содержание ONS 15454 Series
Страница 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 126: ...4 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 4 Turn Up Node NTP A256 Set Up SNMP ...
Страница 168: ...5 42 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 5 Turn Up Network NTP A172 Create a Logical Network Map ...
Страница 304: ...10 8 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 10 Change Node Settings NTP A87 Change SNMP Settings ...
Страница 410: ...16 4 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 16 Power Down the Node NTP A114 Power Down the Node ...
Страница 510: ...17 100 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 17 DLPs A1 to A99 DLP A99 Determine Available VLANs ...
Страница 746: ...20 102 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 20 DLPs A300 to A399 DLP A399 Install a UBIC H EIA ...
Страница 828: ...A 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...