19-59
Cisco ONS 15454 Procedure Guide, R5.0
September 2005
Chapter 19 DLPs A200 to A299
DLP-A294 Perform a Manual Span Upgrade on a Four-Fiber BLSR
Note
BLSR PCA circuits, if present, will remain in their existing STSs. Therefore, they will be located on the
working path of the upgraded span and will have full BLSR protection. To route PCA circuits on
protection channels in the upgraded span, delete and recreate the circuits after the span upgrade. For
example, if you upgrade an OC-48 span to an OC-192, PCA circuits on the protection STSs (STSs 25 to
48) in the OC-48 BLSR will remain in their existing STSs (STSs 25 to 48) which are working, protected
STSs in the OC-192 BLSR. Deleting and recreating the OC-48 PCA circuits moves the circuits to STSs
96 to 192 in the OC-192 BLSR. To delete circuits, see the
“NTP-A278 Modify and Delete Overhead
Circuits” procedure on page 9-4
. To create circuits, see
Chapter 6, “Create Circuits and VT Tunnels.”
Step 1
Apply a Force switch to both span endpoints (nodes) on the span that you will upgrade first. See the
“DLP-A303 Initiate a BLSR Force Ring Switch” task on page 20-3
.
Step 2
Remove the fiber from both working and protect cards at both span endpoints (nodes) and ensure that
traffic is still running.
Step 3
Remove the OC-N cards from both end points.
Step 4
For both ends of the span endpoints, in node view right-click each OC-N slot and choose
Change Card
.
Step 5
In the Change Card dialog box, choose the new OC-N card type.
Step 6
Click
OK
.
Step 7
Complete the
“NTP-A16 Install the OC-N Cards” procedure on page 2-6
to install the new OC-N cards
in both endpoints.
Step 8
Verify that the transmit signal falls within the acceptable range. See
for OC-N
card transmit and receive levels.
Step 9
Complete the
“DLP-A44 Install Fiber-Optic Cables for BLSR Configurations” task on page 17-52
attach the fiber to the cards. Wait for the IMPROPRMVL alarm to clear and the cards to become active.
Step 10
When cards in both endpoint nodes have been successfully upgraded and all the facility alarms (LOS,
SD, or SF) are cleared, remove the forced switch from both endpoints (nodes) on the upgraded span. See
“DLP-A194 Clear a BLSR Force Ring Switch” task on page 18-66
.
Step 11
Perform an exercise ring test to check the BLSR ring functionality without switching traffic. See the
“DLP-A217 BLSR Exercise Ring Test” task on page 19-10
.
Step 12
Repeat these steps for each span in the BLSR. When all spans in the BLSR have been upgraded, the ring
is upgraded.
Step 13
Return to your originating procedure (NTP).
Содержание ONS 15454 Series
Страница 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 126: ...4 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 4 Turn Up Node NTP A256 Set Up SNMP ...
Страница 168: ...5 42 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 5 Turn Up Network NTP A172 Create a Logical Network Map ...
Страница 304: ...10 8 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 10 Change Node Settings NTP A87 Change SNMP Settings ...
Страница 410: ...16 4 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 16 Power Down the Node NTP A114 Power Down the Node ...
Страница 510: ...17 100 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 17 DLPs A1 to A99 DLP A99 Determine Available VLANs ...
Страница 746: ...20 102 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 20 DLPs A300 to A399 DLP A399 Install a UBIC H EIA ...
Страница 828: ...A 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...