22-38
Cisco ONS 15454 Procedure Guide, R5.0
October 2005
Chapter 22 DLPs A500 to A599
DLP-A554 Upgrade Low-Density Electrical Cards in a 1:1 Configuration to High-Density Electrical Cards
Step 6
In node view, right-click the protect slot and change the low-density card to the high-density card:
a.
Choose
Change Card
from the drop-down list.
b.
Choose the new card type (DS3XM-12) from the Change to drop-down list.
c.
Click
OK
.
Step 7
Physically insert the new DS3XM-12 card into the protect slot:
a.
Open the ejectors on the card.
b.
Slide the card into the slot along the guide rails.
c.
Close the ejectors.
Wait for the IMPROPRMVL alarm to clear and the card to become standby. For more information
about LED behavior during DS3XM-12 card bootup, see the
“NTP-A17 Install the Electrical Cards”
.
Step 8
To upgrade a low-density working card, switch traffic onto the protect card from the remaining
low-density card in that 1:1 protect group:
a.
In node view, double-click the remaining DS3XM-6 card from that 1:1 protect group.
b.
Click the
Maintenance > Protection
tabs.
c.
Double-click the protection group that contains that DS3XM-6 card.
d.
In the protection group list, click the newly installed DS3XM-12 card ito highlight it.
e.
Click
Switch
and
Yes
in the Confirmation dialog box.
Step 9
Physically remove the remaining DS3XM-6 card in that protect group:
a.
Open the card ejectors.
b.
Slide the card out of the slot. This raises the
IMPROPRMVL
alarm, which will clear when the upgrade
is complete.
Step 10
In node view, change the DS3XM-6 card to a DS3XM-12 card in CTC:
a.
Right-click the slot where the DS3XM-6 card resided and choose
Change Card
from the drop-down
list.
b.
Choose the new card type (DS3XM-12) from the Change to drop-down list.
c.
Click
OK
.
Step 11
Insert the new DS3XM-12 card into the open slot:
a.
Open the ejectors on the card.
b.
Slide the card into the slot along the guide rails.
c.
Close the ejectors.
Wait for the IMPROPRMVL alarm to clear and the card to become standby. For more information
about LED behavior during DS3/EC1-48 card bootup, see the
“NTP-A17 Install the Electrical
Step 12
Clear the switch you performed in
:
a.
Double-click the first DS3XM-12 card you installed.
b.
In the
Maintenance
>
Protection
tabs, double-click the protection group that contains the reporting
card.
c.
Click the card in the selected group to highlight the card.
d.
Click
Clear
and click
Yes
in the confirmation dialog box.
Содержание ONS 15454 Series
Страница 28: ...Tables xxviii Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 44: ...Tasks xliv Cisco ONS 15454 Procedure Guide R5 0 December 2004 ...
Страница 53: ...liii Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 55: ...lv Cisco ONS 15454 Procedure Guide R5 0 December 2004 About this Guide Document Conventions ...
Страница 126: ...4 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 4 Turn Up Node NTP A256 Set Up SNMP ...
Страница 168: ...5 42 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 5 Turn Up Network NTP A172 Create a Logical Network Map ...
Страница 304: ...10 8 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 10 Change Node Settings NTP A87 Change SNMP Settings ...
Страница 410: ...16 4 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Chapter 16 Power Down the Node NTP A114 Power Down the Node ...
Страница 510: ...17 100 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 17 DLPs A1 to A99 DLP A99 Determine Available VLANs ...
Страница 746: ...20 102 Cisco ONS 15454 Procedure Guide R5 0 March 2005 Chapter 20 DLPs A300 to A399 DLP A399 Install a UBIC H EIA ...
Страница 828: ...A 14 Cisco ONS 15454 Procedure Guide R5 0 December 2004 Appendix A CTC Information and Shortcuts Equipment Inventory ...
Страница 850: ...Index IN 22 Cisco ONS 15454 Procedure Guide R5 0 December 2004 description 4 11 remove 18 23 ...