2-97
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
RMON Messages
RMON Messages
Error Message
RMON-5-FALLINGTRAP: Falling trap is generated because the value of
[chars] has fallen below the falling-threshold value [dec].
Explanation
A falling trap has been generated. The value of the specified MIB object is below the
falling threshold value. [chars] is the MIB object, and [dec] is the threshold value.
Recommended Action
Take appropriate action on the specified MIB object.
Error Message
RMON-5-RISINGTRAP: Rising trap is generated because the value of
[chars] exceeded the rising-threshold value [dec].
Explanation
A rising trap has been generated. The value of the specified MIB object is above the
rising threshold value. [chars] is the MIB object, and [dec] is the threshold value.
Recommended Action
Take appropriate action on the specified object.
SCHED Messages
Error Message
SCHED-3-UNEXPECTEDEVENT: [traceback] [process information] Process
received unknown event (maj [hex], min [hex])
Explanation
A process did not handle an event. The first [hex] is the major event number, and the
second [hex] is the minor event number.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information.
SDM Messages
Error Message
SDM-6-MISMATCH_ADVISE: [chars].
Note
This message applies only to the Catalyst 3750-X and 3750-E switches.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...