2-91
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
POWERNET_ISSU Messages
Error Message
PORT_SECURITY-6-VLAN_FULL: Vlan [dec] on port [chars] has reached its
limit. Address [enet] has been removed.
Explanation
The voice VLAN is the same as the access VLAN. Because the maximum number of
MAC addresses allowed on the access VLAN has been reached, the specified Ethernet address has
been deleted. [dec] is the VLAN ID, [chars] is the port assigned to the voice VLAN and the access
VLAN, and [enet] is the Ethernet address.
Recommended Action
No action is required.
Error Message
PORT_SECURITY-6-VLAN_REMOVED: VLAN [int] is no longer allowed on port
[chars]. Its port security configuration has been removed.
Explanation
A configured VLAN is not allowed either due to a port mode change or an allowed
VLAN list change and is removed from the configuration. [int] is the VLAN ID, and [chars] is the
switch port assigned to the VLAN.
Recommended Action
No action is required.
POWERNET_ISSU Messages
Error Message
POWERNET_ISSU-4-SM_EW_DOMAIN_MISMATCH: Energywise domain of
EtherSwitch is [chars], recommended to have [chars].
Explanation
The EnergyWise domain of the service module does not match that of the switch. The
first [chars] is the EnergyWise domain of the service module. The second [chars] is the EnergyWise
domain of the router.
Recommended Action
Configure the EnergyWise domain of the service module to match that of the
switch. If the message recurs, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit
to look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information.
Note
This message applies only to the Catalyst 3750-X and 3560-X switches.