2-48
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
ILPOWER Messages
Error Message
ILPOWER-5-IEEE-DISCONNECT: Interface [chars]: PD removed.
Explanation
The powered device is not connected to the switch, or the connected powered device is
being powered by an external AC power source. The switch is no longer providing power to the port.
[chars] is the interface.
Recommended Action
No action is required.
Error Message
ILPOWER-5-ILPOWER_POWER_CDP_SHUT: Interface [chars]: inline power shut
Explanation
Inline power is shut down because CDP consumption power on this PoE port is greater
than the allocation power, the hardware interface limit, the user-configured maximum power, or the
available power on this switch. [chars] is the interface.
Recommended Action
No action is required.
Error Message
ILPOWER-5-ILPOWER_POWER_DENY: Interface [chars]: inline power denied.
Explanation
There is not enough power remaining in the switch to supply to the PoE port. [chars] is
the interface.
Recommended Action
Connect the powered device to an external AC power source.
Error Message
ILPOWER-5-INVALID_IEEE_CLASS: Interface [chars]: has detected invalid
IEEE class: [dec] device. Power denied
Explanation
The powered device has an invalid IEEE class so that the switch is not providing power
to the device. [chars] is the interface. [dec] is the IEEE class number.
Recommended Action
No action is required.
Error Message
ILPOWER-5-LINKDOWN_DISCONNECT: Interface [chars]: Link down
disconnect.
Explanation
The powered device is no longer connected to the switch, or the connected powered
device is being powered by an external AC power source. The switch is no longer providing power
on the interface. [chars] is the interface.
Recommended Action
No action is required.
Error Message
ILPOWER-5-POLICE_POWER_INVALID: Interface [chars]: invalid power
police [dec] milliwatts current [dec] mA voltage [dec] mV
Explanation
The power policing current or voltage value is invalid. [chars] is the interface. The first
[dec] is the power policing limit (cutoff value in mW), the second [dec] is the power usage in mA,
and the third [dec] is the power usage in mV.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...