Error Message
PLATFORM_STACKPOWER-4-GLS_EVENT: Switch [dec] experienced a graceful
load shed event
Explanation
The switch shut down because of a sustained overload condition (SOC). [dec] is the
stack member number. A SOC occurs if the power supplies carry a load of twice (or more) the rated
output for 20 ms or longer.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-ILS_EVENT: Switch [dec] experienced an immediate
load shed event
Explanation
The switch shut down because of a power supply failed (PS_FAIL) condition. [dec] is
the stack member number.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-SRLS_EVENT: Switch [dec] experienced a system
ring load shed event
Explanation
The switch shut down because of a system ring load shed (SRLS) event. [dec] is the
stack member number. One example of an SRLS event is a situation in which a switch is physically
removed from the power stack by a cable removal and that switch is a sourcing system in a ring
topology.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...