2-66
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PLATFORM_PM Messages
Error Message
PLATFORM_PBR-4-SDM_MISMATCH: [chars] requires sdm template routing.
Explanation
The routing template is not enabled. [chars] is the text string PBR.
Recommended Action
Modify the SDM template to enable the routing template. Use the
sdm prefer
routing configuration command, and then reload the switch by using the
reload
privileged EXEC
command.
PLATFORM_PM Messages
Error Message
PLATFORM_PM-3-IFCOUNTERROR: Unit number [dec] of interface [chars] is
more than max allowed value of [dec].
Explanation
There are too many interfaces configured for the interface type. [dec] is the interface
count, [chars] is the interface, and [dec] is the maximum number of interfaces.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_PM-3-INTVLANINUSE: internal vlan-id [dec] allocated for
interface [chars] is still in use.
Explanation
An internal VLAN ID allocated for an interface is still in use. [dec] is the VLAN ID,
and [chars] is the interface.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_PM-3-NOINTVLAN: internal vlan of interface [chars] is not
active for vlan-id [dec].
Explanation
The internal vlan_data is not active for the given VLAN ID. [chars] is the interface, and
[dec] is the VLAN ID.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.