2-108
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
STACKMGR Messages
Error Message
STACKMGR-3-NORECORD: Switch removed event for switch [dec] with no
switch record.
Explanation
The stack manager received a switch-removed event for which there is no switch record.
[dec] is the switch number.
Recommended Action
No action is required.
Error Message
STACKMGR-4-MASTER_ELECTED: Switch [dec] has been elected as MASTER of
the stack.
Explanation
The specified switch has been elected stack master. [dec] is the switch number of the
elected stack master.
Recommended Action
No action is required.
Error Message
STACKMGR-4-STACK_LINK_CHANGE: Stack Port [chars] Switch [dec] has
changed to state [chars].
Explanation
The specified stack port status has changed state to up or down. The first [chars] is the
stack port (1 or 2), [dec] is the switch number, and the second [chars] is the new state (up or down).
Recommended Action
No action is required.
Error Message
STACKMGR-4-SWITCH_ADDED: Switch [dec] has been ADDED to the stack.
Explanation
The specified stack member switch has been added to the stack. [dec] is the switch
number.
Recommended Action
No action is required.
Error Message
STACKMGR-4-SWITCH_ADDED_SDM: Switch [dec] has been ADDED to the stack
(SDM_MISMATCH).
Explanation
The specified switch has been added to the stack. [dec] is the switch number.
SDM_MISMATCH means that the added switch cannot support the SDM template that the stack
master is using. Subsequent SDM-6-MISMATCH_ADVISE messages explain the mismatch and
recommend corrective actions.
Recommended Action
No action is required unless SDM_MISMATCH is displayed. For
SDM_MISMATCH corrective actions, see SDM-6-MISMATCH_ADVISE.
Error Message
STACKMGR-4-SWITCH_ADDED_VM: Switch [dec] has been ADDED to the stack
(VERSION_MISMATCH).
Explanation
A switch that has been added to the stack has a different software version. [dec] is the
switch number.
Recommended Action
No action is required.