Chapter 2 Message and Recovery Procedures
PLATFORM_STACKPOWER Messages
Error Message
PLATFORM_STACKPOWER-4-SSLS_EVENT: Switch [dec] experienced a system
star load shed event
Explanation
The switch shut down because of a system star load shed (SSLS) event. [dec] is the stack
member number. One example of an SSLS event is a situation in which a switch is physically
removed from the power stack by a cable removal and that switch is a sourcing system in a star
topology.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-UVLS_EVENT: Switch [dec] experienced an under
voltage load shed event
Explanation
The switch shut down because of a low-voltage condition. [dec] is the stack member
number.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-REDUNDANCY_LOSS: Switch [dec]...[dec] power
stack lost redundancy and is now operating in power sharing mode
Recommended Action
The switch stack with this switch has lost redundancy and is operating in power
sharing mode. [dec] ... [dec] are the stack member numbers that operate in power sharing mode.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-BISP: Switch [dec] experienced a BISP event
Explanation
A built-in self protection (BSIP) event occurred. [dec] is the stack member number.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...