Error Message
PAGP_DUAL_ACTIVE-3-REGISTRY_ADD_ERR: Failure in adding to [chars]
registry
Explanation
The switch could not add a function to the registry. [chars] is the registry name.
Recommended Action
No action is required.
PHY Messages
Error Message
PHY-4-BADTRANSCEIVER: An inappropriate transceiver has been inserted
in interface [chars].
Explanation
A transceiver that should not be used is in the specified interface.
Recommended Action
Remove the transceiver. If the transceiver is a Cisco device, contact your Cisco
technical support representative.
Error Message
PHY-4-CHECK_SUM_FAILED: SFP EEPROM data check sum failed for SFP
interface [chars].
Explanation
The SFP module was identified as a Cisco SFP module, but the system cannot read the
vendor data information to verify whether it is correct. [chars] is the interface in which the SFP
module is installed.
Recommended Action
Remove and then reinsert the SFP module. If it fails again with the same error
message, the SFP module might be defective.
Error Message
PHY-4-EXCESSIVE_ERRORS: Excessive FCS, data, or idle word errors found
on interface [chars].
Explanation
The system detected excessive frame check sequence (FCS), data word, or idle word
errors on the specified interface. [chars] is the interface.
Recommended Action
Enter the
show interface
privileged EXEC command
on the specified
interface, and check for cyclic redundancy check (CRC) and other input errors. If errors are
excessive, enter the
shutdown
interface configuration command and then the
no shutdown
interface
configuration command to reset the interface.
Error Message
PHY-4-MODULE_DUP: SFPs in [chars] and in [chars] have duplicate
vendor-id and serial numbers.
Explanation
The SFP module was identified as a Cisco SFP module, but its vendor ID and serial
number match that of another SFP module in the system. The first [chars] is the interface in which
the SFP module is installed, the second [chars] is the interface where the duplicate SFP module is
installed.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...