2-70
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PLATFORM_STACKPOWER Messages
Error Message
PLATFORM_SPAN-3-PACKET_DROP: Decreases egress SPAN rate.
Explanation
Egress SPAN rates are falling because SPAN is enabled with multicast routing or
fallback bridging.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
PLATFORM_STACKPOWER Messages
Note
These messages apply only to the Catalyst 3750-X switch.
Error Message
PLATFORM_STACKPOWER-6-CABLE_EVENT: Switch [dec] stack power cable
[chars][chars]
Explanation
One of the power cables connected to the switch stack has been inserted or removed.
[dec] is the stack member number. The first [chars] is the power cable number: 1 is for the main
power cable or 2 is for the redundant power cable. The second [chars] is the power cable status; 1 if
the cable is inserted or 2 if the cable is removed.
Recommended Action
No action is required.
Error Message
PLATFORM_STACKPOWER-6-LINK_EVENT: Switch [dec] stack power protocol is
up on cable [chars]
Explanation
One of the power cables can now provide power to the switch stack. [dec] is the stack
member number. [chars] is the power cable number: 1 for the main power cable; 2 for the redundant
power cable.
Recommended Action
No action is required.
Error Message
PLATFORM_STACKPOWER-4-TOO_MANY_ERRORS: Switch [dec] Too many errors
seen on port [chars]
Explanation
There are too many errors on the port providing power to the switch stack. [dec] is the
stack member number. [chars] is the port (1 or 2).
Recommended Action
Verify the stack cable connections. If the stack port is shut down, enable it. If
the message appears again, copy the message exactly as it appears on the console or in the system
log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit
to look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...