2-92
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PT Messages
PT Messages
Error Message
PT-3-PT_HW_UNAVAIL: Protocol Tunneling hardware resource not
available. [chars]
Explanation
Protocol tunneling could not be enabled because no redirect registers are available.
Protocol tunneling requires redirect registers. [chars] is the hardware resource that is not available.
Recommended Action
Disable any applications that use redirect registers, and try configuring the
protocol tunneling again.
QOSMGR Messages
Error Message
QOSMGR-3-FEATURE_NOT_FOUND: Cannot find feature for [chars].
Explanation
An internal software error has occurred. [chars] is the description of the feature that the
software cannot find.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
QOSMGR-3-FILTERTYPE_INVALID: Internal Error Invalid Policy filtertype
[dec].
Explanation
An internal software error has occurred. [dec] is the invalid filter type identification.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
QOSMGR-3-MERGE_RES_COUNT: Internal Error Invalid count.
Explanation
An internal software error has occurred.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...