2-30
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
EC Messages
Error Message
EC-5-CANNOT_BUNDLE1: Port-channel [chars] is down, port [chars] will
remain stand-alone.
Explanation
The aggregation port is down. The port remains standalone until the aggregation port is
up. The first [chars] is the EtherChannel, and the second [chars] is the port number.
Recommended Action
Ensure that the other ports in the bundle have the same configuration]
Error Message
EC-5-CANNOT_BUNDLE2: [chars] is not compatible with [chars] and will
be suspended ([chars])
Explanation
The interface has different interface attributes than the EtherChannel or the other ports
in the EtherChannel. For the interface to join the bundle (EtherChannel), change the interface
attributes to match the EtherChannel attributes. The first [chars] is the interface to be bundled, the
second [chars] is the physical interface (a switch port or a routed port) that is already in the bundle,
and the third [chars] is the reason for the incompatibility.
Recommended Action
Change the interface attributes to match the EtherChannel attributes.
Error Message
EC-5-CANNOT_BUNDLE_LACP: [chars] is not compatible with aggregators in
channel [dec] and cannot attach to them ([chars]).
Explanation
The port has different port attributes than the port channel or ports within the port
channel. [chars] is the incompatible port, [dec] is the channel group number, and the last [chars] is
the reason.
Recommended Action
For the port to join the EtherChannel bundle, change the port attributes so that
they match the port.
Error Message
EC-5-COMPATIBLE: [chars] is compatible with port-channel members.
Explanation
A port was not operational because its attributes were different from those of the port
channel or ports within the port channel. The system has detected that the attributes of the port now
match the port-channel attributes. [chars] is the affected port.
Recommended Action
No action is required.
Error Message
EC-5-DONTBNDL: [chars] suspended: incompatible remote port with
[chars]
Explanation
The configuration of the remote port is different from the configuration of other remote
ports in the bundle. A port can only join the bundle when the configuration of the local port and the
configuration of the remote port are the same as other ports already in the bundle. The first [chars]
is the name of the local interface that is being suspended, and the second [chars] is the name of the
local interface that is already bundled.
Recommended Action
Make sure that the configuration of the remote ports is the same for all ports in
the bundle.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...