2-78
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PLATFORM_STACKPOWER Messages
Error Message
PLATFORM_STACKPOWER-4-BISP_POE_PORT: Switch [dec] experienced a port
BISP event
Explanation
A built-in self protection (BISP) event that affected Power over Ethernet (PoE)
occurred. [dec] is the stack member number.
Recommended Action
No action is required.
Error Message
PLATFORM_STACKPOWER-4-BISP_PORT_A_SC: Switch [dec] experienced a
short-circuit BISP event on port 1
Explanation
A short-circuit built-in self protection (BISP) event occurred on port 1 of the switch.
[dec] is the stack member number.
Recommended Action
Disable and then enable port 1 of the switch. If the message appears again, copy
the message exactly as it appears on the console or in the system log. Research and attempt to
resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported
problems. If you still require assistance, open a case with the TAC, or contact your Cisco technical
support representative, and provide the representative with the gathered information. For more
information about these online tools and about contacting Cisco, see the
“Error Message Traceback
Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-BISP_PORT_B_SC: Switch [dec] experienced a
short-circuit BISP event on port 2
Explanation
A short-circuit built-in self protection (BISP) event occurred on port 2 of the switch.
[dec] is the stack member number.
Recommended Action
Disable and then enable port 2 of the switch. If the message appears again, copy
the message exactly as it appears on the console or in the system log. Research and attempt to
resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported
problems. If you still require assistance, open a case with the TAC, or contact your Cisco technical
support representative, and provide the representative with the gathered information. For more
information about these online tools and about contacting Cisco, see the
“Error Message Traceback
Reports” section on page 1-7
.
Error Message
PLATFORM_STACKPOWER-4-BISP_NBR_DEAD: Switch [dec] [dec] neighbor
experienced a major BISP event
Explanation
A major built-in self protection (BISP) event shut down the neighbor of the switch. The
first [dec] and second [dec] are the stack member numbers on each side of the neighbor.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...