2-90
Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PORT_SECURITY Messages
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see
Error
Message Traceback Reports, page 1-7
.
PORT_SECURITY Messages
Error Message
PORT_SECURITY-2-PSECURE_VIOLATION:Security violation occurred caused
by MAC [enet] on port [chars].
Explanation
An unauthorized device attempted to connect on a secure port. [enet] is the MAC
address of the unauthorized device, and [chars] is the secure port.
Recommended Action
Identify the device that attempted to connect on the secure port. Notify your
network system administrator of this condition.
Error Message
PORT_SECURITY-2-PSECURE_VIOLATION_VLAN: Security violation on port
[chars] due to MAC address [enet] on VLAN [dec]
Explanation
An unauthorized device attempted to connect on a secure trunk port. [chars] is the
secure port, [enet] is the MAC address of the unauthorized device, and [dec] is the VLAN ID.
Recommended Action
Identify the device that attempted to connect through the secure trunk port.
Notify your network system administrator of this condition.
Error Message
PORT_SECURITY-6-ADDR_REMOVED: Address [dec]:[enet] exists on port
[chars]. It has been removed from port [chars].
Explanation
A routed port is reconfigured as a switch port. The address in the previous switch
configuration conflicts with the running configuration and has been deleted. [dec]:[enet] is the MAC
address of the port, and [chars] is the reconfigured port.
Recommended Action
No action is required.
Error Message
PORT_SECURITY-6-ADDRESSES_REMOVED: Maximum system secure address count
reached. Some secure addresses configured on port [chars] removed.
Explanation
Some configured and sticky MAC addresses on the specified port were removed from
the configuration. The number of secure addresses that the system supports was exceeded. This
condition occurs only during hot swapping or port-mode changes (for example, when the port is
converted from a Layer 3 to a Layer 2 port). [chars] is the port.
Recommended Action
No action is required.
Содержание Catalyst 3560-E Series
Страница 6: ...Contents vi Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...
Страница 10: ...x Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 Preface ...
Страница 150: ...Index IN 6 Catalyst 3750 X 3750 E 3560 X and 3560 E Switch System Message Guide OL 9772 05 ...