Catalyst 3750-X, 3750-E, 3560-X, and 3560-E Switch System Message Guide
OL-9772-05
Chapter 2 Message and Recovery Procedures
PLATFORM Messages
Error Message
PIMSN-6-IGMPSN_VLAN: PIM Snooping runtime mode on vlan [dec] [chars]
due to IGMP Snooping [chars].
Explanation
When IGMP snooping is disabled, PIM snooping is disabled. When IGMP snooping is
re-enabled, PIM snooping is re-enabled. [dec] is the VLAN ID, the first [chars] is the PIM snooping
mode, and the second [chars] is the IGMP snooping mode.
Recommended Action
No action is required.
PLATFORM Messages
Error Message
PLATFORM-1-CRASHED: [chars].
Explanation
The system is trying to display the failure message from the previous failure. [chars] is
the description of the error message.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.
Error Message
PLATFORM-3-NO_HARDWARE_RESOURCES: Not enough hardware resources.
Shutting down [chars].
Explanation
There are too many VLANs and routed ports. [chars] is the short interface name, such
as Gi1/0/1, or the VLAN name, such as VLAN0002.
Recommended Action
Reduce the total number of VLANs and routed ports to be less than 1023. To
preserve configurations and connections across reboots, save the configuration.
Error Message
PLATFORM-3-PW_REC_HRPC_BAD_LENGTH: Received incompatible length
(=[dec]) in set-password-recovery HRPC message from box [dec].
Note
This message applies only to the Catalyst 3750-X and 3750-E switches.
Explanation
The system received an incompatible length parameter in the set-password-recovery
HRPC message. This can be caused by a stack operating with incompatible software versions on
different stack members. The first [dec] is the length and the second [dec] is the switch.
Recommended Action
Make sure that all stack members are running compatible software images. If the
message appears again, copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with the gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error
Message Traceback Reports” section on page 1-7
.