62-11039
7-113
Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
229 SERVICE SOON--PM #4 DUE
•
TRIGGER–ON: The Maintenance Hour Meter #4 time has expired.
TRIGGER ON: The Maintenance Hour Meter #4 time has expired.
•
Alarm Light will NOT be turned on.
•
RESET CONDITION: Alarm may be manually reset via keypad.
1.
Check Unit Maintenance Records
a. Schedule unit into service facility for
maintenance
Must be done soon!
2.
Perform Maintenance
a. Perform appropriate engine & unit
maintenance
Follow instructions on proper maintenance form
3.
Reset Maintenance Hour Meter #4
a. Check that Maintenance Hour
Meter #4 interval is set for your
requirements.
b. Reset Maintenance Hour Meter #4 for
the next service interval
Reset Interval in Configuration List as required.
Hour Meter is reset in the Functional Parameter list.
Follow maintenance interval recommendations in
Section 8.1.
230 SERVICE SOON--PM #5 DUE
•
TRIGGER–ON: The Maintenance Hour Meter #5 time has expired.
GG
O
e a te a ce ou
ete #5 t e as e p ed
•
UNIT CONTROL: Alarm Only. Alarm Light will NOT be turned on.
•
RESET CONDITION: Alarm may be manually reset via keypad.
1.
Check Unit Maintenance Records
a. Schedule unit into service facility for
maintenance
Must be done soon!
2.
Perform Maintenance
a. Perform appropriate engine & unit
maintenance
Follow instructions on proper maintenance form
3.
Reset Maintenance Hour Meter #5
a. Check that Maintenance Hour
Meter #5 interval is set for your
requirements.
b. Reset Maintenance Hour Meter #5 for
the next service interval
Reset Interval in Configuration List as required.
Hour Meter is reset in the Functional Parameter list.
Follow maintenance interval recommendations in
Section 8.1.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...