3.16 FUNCTIONAL CHANGE (PARAMETERS)
COOL
DEFROST
ALARM
START-STOP
SETPOINT
BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
+36 F
-20
START--STOP/
CONTINUOUS
2
1. Press the SELECT key until the MessageCenter displays
“PRESS
↑↓
TO VIEW SETTINGS”.
2. By pressing the UP ARROW key, you will move through the
Function List beginning at the top or by pressing the DOWN
ARROW key, you will move through the Function List beginning
at the bottom.
3. To change one of the Functions, bring the Function you wish to change into the MessageCenter,
and press the = key. “
↑ ↓
TO SCROLL, THEN = TO SAVE” will show in the MessageCenter.
Pressing either UP or DOWN ARROW key will begin to change the
Function setting. The MessageCenter will flash, indicating that a change has been made that
has not been entered into memory.
4. Continue pressing UP or DOWN ARROW key until the desired value is showing, then press
the = key. The MessageCenter will stop flashing. The new value is now in memory.
If the = key is not pressed within 10 seconds, the MessageCenter will change to
“FUNCTION NOT CHANGED”. This will appear for 5 seconds, then return to the last
Functional Parameter shown. If no further keys are pressed, the default message will be
displayed another 10 seconds.
PRESS
↑ ↓
TO VIEW SETTINGS
NOTE
Any Function that is shown with a padlock sym-
bol cannot be changed from the keypad.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...