62-11039
5-16
5.4 INSTALLING NEW SOFTWARE
5.4.1 Using The Program PC Card
TIP
Whenever performing a major operation to a microprocessor, such as installing new operating software, it is
always a good idea to start the unit and give it a quick check over
prior
to performing the operation.
NOTE
Once the unit shuts down to begin the software install process, the Compressor Suction Modulation Valve
closing process begins. The software installation processes will not begin until the CSMV is completely
closed, which will delay the actual process for about 45 seconds.
CAUTION
The display and MessageCenter may behave differently during the software loading process, de-
pending on the version of software currently in the controller. DO NOT INTERRUPT THE SOFTWARE
INSTALLATION PROCESS ONCE IT HAS STARTED.
2. Insert a Download Card into the PC card slot on
the front of the microprocessor. Be certain that
the instruction label on Download Card is facing
the “Caution” label on the microprocessor. Do
not force card into slot.
5. Press = to load the program. The MessageCenter will go blank. If the engine is running, it will
shut down. After a few seconds, the display will power up, and the MessageCenter will show
INSTALLING PROGRAM SOFTWARE during the software install process. The Card Status
LED adjacent to the PC Card slot will blink together with the Micro Status LED during this
installation process. Once the entire program has been loaded, the MessageCenter will show
INSTALL COMPLETE -- REMOVE CARD. At the same time, the Card Status LED will stop
blinking and be on solid, indicating that the software install is complete.
6. When the card is removed, the Micro will power up as it was prior to inserting the card (PC
Mode or unit running). Allow the Micro to completely power up (Main Display and
MessageCenter displaying appropriate messages) once after installing the new software
before turning the power off, or removing the PC Mode jumper.
DO NOT TURN THE RS
SWITCH OFF DURING THE INITIAL START FOLLOWING A SOFTWARE UPGRADE
.
1. Place the Micro in PC Mode (Refer to Section
5.1), or place the RS switch in the Start/Run
Position.
3. The MessageCenter will show one of 3 different
messages:
Same SW: “= to Load,
↑
To Cancel”
Old SW: “= to Load,
↑
To Cancel”
New SW: “= to Load,
↑
To Cancel”
CAUTION
4. Choose New.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...