3.12 VIEW ACTIVE ALARMS
COOL
DEFROST
ALARM
START-STOP
SETPOINT
BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
NO ACTIVE ALARMS
+36 F
-20
START--STOP/
CONTINUOUS
2
ALARM LIGHT
1. Press the ALARM LIST key. If there are no active alarms, the display
will say “NO ACTIVE ALARMS” for 5 seconds.
3. Press the ALARM LIST or UP ARROW key to scroll through the list of alarms.
4. When you reach the end of the alarm list, “LIST END, = TO CLEAR ALARMS”
is displayed for 5 seconds.
5. To clear the alarm list, press the = key while “LIST END, = TO CLEAR ALARMS” is being dis-
played. “ACTIVE ALARMS LIST CLEAR” is displayed. This will move all Alarms to the Inac-
tive Alarm list.
2. If there are active alarms, the display will be ‘A’ and the alarm number and
message. The last Alarm that occurred will be the first Alarm displayed and so
on.
Alarms that occur are stored in the Alarm List in the
controller.
Stored alarms may be viewed in the
MessageCenter.
For a complete list of alarms, their meanings, and
troubleshooting refer to Section 7.
TIP
Another way to clear active alarms is to turn the
controller OFF and then back ON using the
START/RUN -- OFF switch (RS).
TIP
“CHECK MICROPROCESSOR” means there
is a wiring problem between the microproces-
sor and the display module.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...