1-2
62-11039
WARNING
Be aware of HIGH VOLTAGE (up to 599V)
supplied by the generator as the unit may
start automatically. Before servicing the
unit, make sure the START/RUN--OFF
switch is in the OFF position. Also
disconnect the negative battery cable.
NEVER dis--assemble the generator: HIGH
MAGNETIC FIELD INSIDE! Pacemaker
wearers must stay clear of the unit while
operating as the power generator supplies
HIGH VOLTAGE AND MAGNETIC FIELD.
WARNING
Under no circumstances should ether or
any other starting aids be used to start en-
gine.
WARNING
When performing service and/or mainte-
nance procedures, make certain the unit
is disconnected from the power source
and that the RS is in OFF position so that
it is impossible for the unit to start up au-
tomatically during the maintenance opera-
tion.
WARNING
Make sure the power plug is clean and dry
before connecting to any electrical outlet/
receptacle.
WARNING
Do not connect to any electrical outlet
without checking that it meets the
460/3/60 and 23 Amp electrical
requirements of the unit.
WARNING
Always place RS in the OFF position and
turn off the high voltage power supply be-
fore disconnecting the high voltage power
plug from the unit.
WARNING
Do not place the Start/Run--OFF Switch
(RS) in the Start/Run position or the unit will
start.
WARNING
Do Not Allow Jumper Wire To Touch Any
Ground.
WARNING
Carefully protect eyes from solvent.
WARNING
Do not direct water or steam into the gener-
ator openings. Do not allow any soap and
water solutions to enter the generator.
WARNING
High voltage (dielectric) testing must not be
performed to the machine without first ob-
serving NEMA rules. The insulation of this
generator winding may be safely checked
by using a megohm meter. A high reading
indicates good insulation.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...