6.1 MessageCenter MESSAGES
The following table lists all of the messages which do not appear in other lists in this manual and a description of their
meaning. Refer to Section 7 for a list of Alarm messages. Refer to Section 3.14 for a list of Unit Data messages. Refer
to Section 3.16 for a list of Functional Parameter messages. Refer to Section 5.2.1 for a list of Configuration
messages.
MessageCenter MESSAGES
Message
Description
↑↓
TO SCROLL, THEN = TO LOCK
This message is used when viewing Unit Data. Use the UP &
DOWN arrow keys to move through the Data list. Press the = key
to lock a Data item in the MessageCenter
↑↓
TO SCROLL, THEN = TO SAVE
Press the UP or DOWN arrow keys to scroll through menu selec-
tions available in this mode. When you reach the desired selec-
tion, press the = key to store new value in microprocessor’s
memory.
↑↓
TO SCROLL, THEN = TO SELECT
Press the UP or DOWN arrow keys to scroll through menu selec-
tions available in this mode. When you reach the desired selec-
tion, press the = key to select it.
= TO INSTALL, INSTALLS LEFT XX
An Options PC Card has been inserted into the PC Card slot.
Press = to install the option into the Micro. The number of installs
remaining on the PC Card will be shown.
ACTIVE ALARM LIST CLEARED
The list of active alarms in the Micro alarm has been erased. (This
does
not
remove alarms from the data recorder.)
ALL ALARMS CLEARED
The list of active and inactive alarms in the Micro alarm lists have
been erased. (This does
not
remove alarms from the data record-
er.)
ALL INFO LOADED -- REMOVE CARD
All data has been loaded into the Micro from the PC Card. The
card may be safely removed from the Micro.
CALIBRATION UNSUCCESSFUL
Transducer calibration was unsuccessful.
CANNOT ENTER TRIP START
Cannot enter trip start. A problem has been detected within the
Data Recorder.
CANNOT START DEFROST CYCLE
Cannot start defrost cycle. Refer to Defrost Sections 3.10, 4.4.10,
and 8.24.
CANNOT START PRETRIP
Cannot start pretrip. Refer to Pre Trip Section 3.5.
CARD FULL, REMOVE CARD
The PC Downloader Card is full of downloaded files. There is no
additional room to download the Micro. You may safely remove the
PC Card from the slot.
CARD LOCKED -- REMOVE CARD
The lock switch on the PC Card is in the “Locked” position. To use
the PC Card, move the switch to the “Unlocked” position.
CARD REMOVED, DATA NOT COPIED
The PC Card was removed before all data was copied onto the
card.
CARD REMOVED, REINSERT CARD
The PC Card was removed from the card slot before the operation
was completed. Reinsert the PC Card into the card slot to perform
the operation.
CFG: =TO LOAD,
↑
TO CANCEL
A Configuration Card has been inserted into the PC Card slot.
Press = to load configurations or IntelliSets into microprocessor.
CHANGE INTELLISET TO EXIT
Sleep Mode and IntelliSleep Intelliset is active. Alternates with In-
telliSleep Mode at 5 second interval whether unit is running or not.
CHARGE MODE--HOLD=TO EXIT
Ready to charge system with refrigerant.
CHECK AT NEXT SERVICE INTERVAL
The unit needs to be checked at next service interval.
There is currently an active non--shutdown alarm in the alarm list.
CHECK COOLANT LEVEL
The engine coolant level is not full. (Requires optional sensor)
CHECK ENGINE OIL LEVEL
The oil level in the diesel engine is low. (Requires optional sensor)
CHECK FUEL LEVEL
The level in the fuel tank is very close to empty. (Requires optional
sensor)
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...