![Carrier VECTOR 1800 MT Скачать руководство пользователя страница 170](http://html1.mh-extra.com/html/carrier/vector-1800-mt/vector-1800-mt_operation-and-service-manual_2564194170.webp)
62-11039
7-39
Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
73
NO POWER--CHECK POWER CORD
•
TRIGGER–ON: In standby mode AND no AC power
•
UNIT CONTROL: Engine operation: this alarm will not activate in engine operation. Standby operation: if
the “No Power” configuration is set for “Installed and Shut Down” the refrigeration system will shut down
the No Power configuration is set for Installed and Shut Down the refrigeration system will shut down
with the alarm on and PSCON still energized.
•
RESET CONDITION: Auto Reset when AC power is present AND configuration is set to shutdown or if
the user changes the switch to standby operation or alarm may be manually reset via keypad or by
turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active alarm
should clear itself (see reset condition above). Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
1.
Check Circuit Breaker On The Main Supply
a. Check circuit breaker
50A supply circuit breaker
b. Check the voltage in the plug
480V/3/60Hz
2.
Check Power Cord
a.Inspect connections in the socket and
the plug
Connections must be tight
b. Inspect the cable
Cable must not be frayed, cut or damaged
3.
Check For Power In The Control Box
a.Check for voltage at PSCON L1--L2,
L2--L3, L1--L3
All three readings must be 460V
10%
b. Check for voltage at PSCON2 L1--L2,
L2--L3, L1--L3
All three readings must be 460V
10%
4.
Check Connections
a. Check for bad connections in the
control box
Connections and wire crimps must be tight
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...