62-11039
3-20
Table 3-1. UNIT DATA
* Also appear in Configurations
+ May or may not be displayed depending on functional parameter settings
*
UNIT MODEL #
Unit model number (selected through configurations)
+
HOURS TO ENGINE
MAINT
Number of engine hours until the next programmed engine maintenance.
+
HOURS TO S/B MTR
MAINT
Number of engine hours until the next programmed electric standby mo-
tor maintenance.
+
HOURS TO UNIT MAINT
Number of switch--on hours until the next programmed general unit
maintenance.
+
TIME LEFT TO PM (1--5)
Number of hours until the next programmed maintenance.
*
PRODUCTSHIELD SETUP: Indicates that unit has IntelliSet installed and displays ProductShield set-
tings.
PRODUCTSHIELD
ECONO:
Indicates if ProductShield Econo is
OFF
OR
Go To Start/Stop
OR
Go
To Continuous Run
ECONO MIN TEMP
Minimum ambient temperature of range for activation of ProductShield
Econo (Will only be displayed if Econo is
NOT OFF
)
ECONO MAX TEMP
Maximum ambient temperature of range for activation of ProductShield
Econo (Will only be displayed if Econo is
NOT OFF
)
ECONO DELTA--T
Delta--T value for activation of ProductShield Econo (Will only be dis-
played if Econo is
NOT OFF
)
PRODUCTSHIELD HIGH
AIR:
Indicates if Product Shield High Air is
ON
or
OFF
HIGH AIR MIN TEMP
Minimum ambient temperature of range for activation of Product Shield
High Air (Will only be displayed if High Air is
ON
)
HIGH AIR MAX TEMP Maximum ambient temperature of range for activation of Product Shield
High Air (Will only be displayed if High Air is
ON
)
HIGH AIR DELTA--T
Delta--T value for activation of Product Shield High Air (Will only be dis-
played if High Air is
ON
)
PRODUCTSHIELD:
WINTER -- xx
°
Indicates the ambient temperature that is controlling ProductShield Win-
ter (Will only be displayed if WINTER is
NOT OFF
)
*
+
RANGE 1 LOCK
Compartment 1 Only
OFF -- Temperature Range 1 Lock is turned off.
CONTINUOUS -- When the setpoint is set between Range 1 Minimum &
Maximum Temperatures, the unit is set to operate only in Continuous
Run.
START--STOP -- When the setpoint is set between Range 1 Minimum &
Maximum Temperatures, the unit is set to operate only in Start--Stop.
*
+
RANGE 1 MINIMUM TEMP
This is the lower limit for Range 1.
*
+
RANGE 1 MAXIMUM TEMP This is the upper limit for Range 1.
*
+
RANGE 2 LOCK
Compartment 1 Only
OFF -- Temperature Range 2 Lock is turned off.
CONTINUOUS -- When the setpoint is set between Range 2 Minimum &
Maximum Temperatures, the unit is set to operate only in Continuous
Run.
START--STOP -- When the setpoint is set between Range 2 Minimum &
Maximum Temperatures, the unit is set to operate only in Start--Stop.
*
+
RANGE 2 MIN. TEMP
This is the lower limit for Range 2.
*
+
RANGE 2 MAX. TEMP
This is the upper limit for Range 2.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...