8.27 CONDENSER COIL
8.27.1 Coil Cleaning
Remove all foreign material from the condenser coil by
reversing the normal air flow. (Air is pulled in through the
front and discharges over the engine.) Compressed air or
water may be used as a cleaning agent. It may be
necessary to use warm water mixed with any good
commercial dishwasher detergent. Rinse coil with fresh
water if a detergent is used.
8.27.2 Coil Replacement
a. Remove the refrigerant charge per section 8.10.
b. Drain engine coolant.
c. Remove the condenser grille.
d. Unsolder discharge line and remove the line to the
receiver.
e. Remove coil mounting hardware and remove the
coil.
f. Install replacement coil and solder connections.
g. Leak-check the coil per section 8.11. Evacuate the
unit per section 8.12, then charge the unit with refrig-
erant per section 8.12.4.
h. Refill engine coolant.
8.28 CONTROLLER SENSOR CHECKOUT
An accurate ohmmeter must be used to check
resistance values shown in Table 8-8.
Due to variations and inaccuracies in ohmmeters,
thermometers or other test equipment, a reading within
2% of the chart value would indicate a good sensor. If a
sensor is bad, the resistance reading will usually be
much higher or lower than the resistance values given in
Table 8-8.
Two preferred methods of determining the actual test
temperature at the sensor, is an ice bath at 32
_
F (0
_
C)
or a calibrated temperature tester.
Table 8-8. Sensor Resistance (ATT, 1RAT, 2RAT, 3RAT, 1SAT, ENCT, EVOT, CST, 1DTT, 2DTT)
°
F
°
C
Ohms
°
F
°
C
Ohms
°
F
°
C
Ohms
°
F
°
C
Ohms
--40
--40
336,500
18
--7.8
49,060
76
24.4
10,250
134
56.7
2,809
--38
--38.9
312,600
20
--6.7
46,230
78
25.6
9,760
136
57.8
2,697
--36
--37.8
290,600
22
--5.6
43,580
80
26.7
9,299
138
58.9
2,590
--34
--36.7
270,300
24
--4.4
41,100
82
27.8
8,862
140
60.0
2,488
--32
--35.6
251,500
26
--3.3
38,780
84
28.9
8,449
142
61.1
2,390
--30
--34.4
234,200
28
--2.2
36,600
86
30.0
8,057
144
62.2
2,297
--28
--33.3
218,200
30
--1.1
34,560
88
31.1
7,686
146
63.3
2,208
--26
--32.2
203,400
32
0
32,650
90
32.2
7,334
148
64.4
2,124
--24
--31.1
189,700
34
1.1
30,850
92
33.3
7,000
150
65.6
2,042
--22
--30
177,000
36
2.2
29,170
94
34.4
6,684
155
68.3
1,855
--20
--28.9
165,200
38
3.3
27,590
96
35.6
6,384
160
71.1
1,687
--18
--27.8
154,300
40
4.4
26,100
98
36.7
6,099
165
73.9
1,537
--16
--26.7
144,200
42
5.5
24,700
100
37.8
5,828
170
76.7
1,402
--14
--25.6
134,800
44
6.6
23,390
102
38.9
5,571
175
79.4
1,281
--12
--24.4
126,100
46
7.7
22,160
104
40.0
5,327
180
82.2
1,171
--10
--23.3
118,100
48
8.9
20,990
106
41.1
5,095
185
85.0
1,072
--8
--22.2
110,500
50
10
19,900
108
42.2
4,874
190
87.8
983
--6
--21.1
103,600
52
11.1
18,870
110
43.3
4,665
195
90.6
902
--4
--20
97,070
54
12.2
17,900
112
44.4
4,465
200
93.3
829
--2
--18.9
91,030
56
13.3
16,980
114
45.5
4,275
205
96.1
762
0
--17.8
85,400
58
14.4
16,120
116
46.7
4,095
210
98.9
702
2
--16.7
80,160
60
15.5
15,310
118
47.8
3,923
215
101.7
647
4
--15.6
75,270
62
16.6
14,540
120
48.9
3,759
220
104.4
598
6
--14.4
70,720
64
17.7
13,820
122
50.0
3,603
225
107.2
553
8
--13.3
66,460
66
18.9
13,130
124
51.1
3,454
230
110.0
511
10
--12.2
62,500
68
20.0
12,490
126
52.2
3,313
235
112.8
473
12
--11.1
58,790
70
21.1
11,880
128
53.3
3,177
240
115.6
438
14
--10.0
55,330
72
22.2
11,310
130
54.4
3,049
245
118.3
406
16
--8.9
52,090
74
23.3
10,760
132
55.6
2,926
250
121.1
378
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...