7-64
62-11039
Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
134 CHEK REMOTE TEMP SENSOR 2 (2 Compartment Units Only)
•
TRIGGER–ON: Remote Temperature Sensor 2 is not within the maximum range of --53
°
F to +158
_
F
(--47
°
C to +70
°
C)
(
)
•
UNIT CONTROL: Alarm only.
•
RESET CONDITION: Auto Reset when Remote Temperature Sensor 2 is in range or, alarm may be
manually reset via keypad or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active alarm
should clear itself (see reset condition above). Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
1.
Check Remote Temp Sensor 2
a. Inspect Remote Temp Sensor 2 &
connector
No damage to sensor
No damage, moisture, or corrosion in connector
b. Check Remote Temp Sensor 2
resistance (See Note 4)
(Refer to Table 8-8 for complete resistance chart)
10,000 Ohms @ 77
°
F (25
°
C)
2.
Check Remote Temp Sensor 2 Wiring
a. Inspect harness & control box
connector pins & terminals (See
wiring schematic)
No physical damage to harness.
No damaged or corroded pins
136
C2 CHK SUPPLY AIR SENSOR (2 Compartment Units Only)
•
TRIGGER–ON: Supply Air Temp Sensor 2 is not within the range of --53
°
F to +158
°
F (--47
°
C to +70
°
C)
•
UNIT CONTROL: Engine and standby operation: alarm only
•
UNIT CONTROL: Engine and standby operation: alarm only.
•
RESET CONDITION: Auto Reset when sensor is in range or, alarm may be manually reset via keypad or
by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, the active alarm
should clear itself (see reset condition above). Operate the unit through the appropriate modes to see if any active
alarm occurs. Continue with the steps below as necessary.
1.
Check Supply Air Temp Sensor 2
a. Inspect Remoter Temp Sensor &
connector
No damage to sensor
No damage, moisture, or corrosion in connector
b. Check
Remote
Temp
Sensor
resistance (See Note 4)
(Refer to Table 8-8 for complete resistance chart)
10,000 Ohms @ 77
°
F (25
°
C)
2.
Check Supply Air Temp 2 Wiring
a. Inspect harness & control box
connector pins & terminals (See
wiring schematic)
No physical damage to harness.
No damaged or corroded pins
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...