7-88
62-11039
Alarm
NO.
Steps
ALARM / CAUSE
CORRECTIVE ACTION
P176 C3 CHECK LSV VALVE
•
TRIGGER–ON: Compartment 3 Liquid Solenoid Valve (LSV3) current is outside the range of 0.75A to
2.0A
•
UNIT CONTROL: Engine and standby operation: pre trip will fail and display “PRE TRIP FAIL AND
•
UNIT CONTROL: Engine and standby operation: pre--trip will fail and display “PRE--TRIP FAIL AND
COMPLETED”.
•
RESET CONDITION: Auto Reset when LSV2 output is active, or alarm may be manually reset via
keypad or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1) Operate the unit through the appropriate modes to see if any active alarm occurs. Continue
with the steps below as necessary.
1.
Check LSV3
a. Inspect component & wire
connections
No damage to coil
No damage, moisture, or corrosion in pins
Use component test mode to check circuit
b. Check resistance of LSV3 coil
Refer to Section 2.14
2.
Check LSV3 Wiring
a. Inspect harness & control box
connector pins & terminals (See
wiring schematic)
No physical damage to harness.
No damaged or corroded pins
P177 CHECK EVAP SUPERHEAT
•
TRIGGER–ON: After microprocessor closes the EVXV, evaporator pressure fails to drop by 20 psig (1.36
Bar) or fails to go below 0 psig
•
UNIT CONTROL: Engine and standby operation: pre trip will fail and display “PRE TRIP FAIL AND
•
UNIT CONTROL: Engine and standby operation: pre--trip will fail and display “PRE--TRIP FAIL AND
COMPLETED”.
•
RESET CONDITION: Auto Reset if pre--trip mode is started again, or alarm may be manually reset via
keypad or by turning the unit off, then back on again.
NOTE: Follow the steps below until a problem is found. Once a repair or correction has been made, clear the
alarm(s). (See Note 1) Operate the unit through the appropriate modes to see if any active alarm occurs. Continue
with the steps below as necessary.
1.
Check Valve
a. Inspect EVXV
Check to see if coil is seated on valve properly.
(S
S
i
f
h ki
d
i i
EVXV)
b. Inspect component and wire
connections
p p y
(See Section 8.17 for checking and servicing EVXV)
c.Check coil resistance
d.Check coil resistance
e. Check basic refrigeration system
f. Check the EVXV electrical system
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...