![Carrier VECTOR 1800 MT Скачать руководство пользователя страница 81](http://html1.mh-extra.com/html/carrier/vector-1800-mt/vector-1800-mt_operation-and-service-manual_2564194081.webp)
62-11039
3-31
3.20 OPTIONS
3.20.1 IntelliSet
COOL
DEFROST
ALARM
START-STOP
SETPOINT
BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
APPLES
ACTIVE
+34 F
+34
START--STOP/
CONTINUOUS
2
DURING START UP
Observe the MessageCenter during the Power--Up process. If the unit is
equipped with IntelliSet, the name of the active or modified IntelliSet
will be displayed for approximately 10 seconds before the engine
starts.
DURING OPERATION
Press the SELECT key to view current IntelliSet. You will be prompted to press
either the “=” key or the UP or DOWN ARROW Key to scroll through list of
IntelliSets. The current IntelliSet will have either the word ACTIVE or
MODIFIED after it. MODIFIED indicates that one or more of the IntelliSet
settings (other than setpoint) have been changed. To change MODIFIED to
ACTIVE, press = key while the IntelliSet is shown in the MessageCenter.
The Advance Microprocessor offers over 48
parameters that may be set depending on the product
being carried. IntelliSet allows the owner to
pre--program specific product settings into the
microprocessor and give the settings a name. The
operator may then call up these settings by simply
selecting the IntelliSet name.
For example: Apples may require continuous operation
at 35
°
F (1.7
°
C) with a defrost every 3 hours while a load
of cheese may require the same operation with
setpoints ranging from 35
°
F to 42
°
F (1.7
°
C to 5.6
°
C)
and a load of ice cream requires Start--Stop operation at
--22
°
F (--30
°
C) with defrost at 12 hour intervals. The
settings required for each product may be entered into
the microprocessor and then locked so they cannot be
changed. In the case of the cheese, the range of
setpoints may be locked, leaving the operator the ability
to change the setpoint within the locked range.
When a load of apples is going to be picked up, the
operator simply selects “APPLES” from the IntelliSet
menu; for cheese, “CHEESE” is selected ; for ice cream,
“ICE CREAM” is selected. With each selection, the
microprocessor automatically re--programs the settings
to provide the best temperature control, fuel economy,
and performance for that particular product.
NOTE
IntelliSet #31 is pre--programmed as
“IntelliSleep” which allows Sleep Mode (See
Section 3.9) to be entered by simply changing
to that IntelliSet.
NOTE
The above settings are
examples
of possible
settings. Except for IntelliSleep, IntelliSets are
not factory set. They are developed by individu-
al customers.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...