3.6 CHANGING SETPOINT
COOL
DEFROST
ALARM
START-STOP
SETPOINT
BOX TEMPERATURE
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
+36 F
-20
START--STOP/
CONTINUOUS
2
2. With the setpoint of the desired compartment displayed, press
the UP ARROW or DOWN ARROW key to change the setpoint
to the desired value. The MessageCenter will show “
↑↓
TO
SCROLL, THEN = TO SAVE”.
3. Press the = key to save the
new setpoint.
1. Wait for desired compart-
ment to be displayed.
SETPOINT CHANGED
Setpoints of --22
°
F to +89.6
°
F (--30
°
C to +32
°
C) may be
entered via the keypad for each compartment. The
controller always retains the last entered setpoint in
memory for each compartment.
Depending on
Microprocessor set--up, the setpoint may be changed
up or down in either 0.1
°
(one--tenth of a degree) or 1
°
(one full degree) increments by pressing and releasing
either the UP ARROW or DOWN ARROW key.
NOTE
Setpoint for a compartment cannot be changed
unless the switch for that compartment is “ON”.
The microprocessor Configurations allow a
Minimum and Maximum Setpoint to be entered,
so that only setpoints within that range may be
selected.
“MAX SETPOINT HAS BEEN
REACHED” or “MIN SETPOINT HAS BEEN
REACHED” WILL APPEAR in the Message-
Center when either of these conditions are met.
You can not change the setpoint when viewing the
Alarm List, Data List or Functional Parameters, or when
unit is in Pretrip or is in Sleep Mode. Setpoint may be
changed any other time the RS is in the START/RUN
position, or with the unit in PC Mode.
Pressing the = key will cause the new displayed setpoint
value to become active and “SETPOINT CHANGED” is
displayed. If the new value is not entered, after 5
seconds of no keypad activity, the entire display and
Light Bar will flash for 15 seconds with “SETPOINT NOT
CHANGED” displayed and then revert back to the last
entered setpoint for that compartment. All other keys
are active at this time and if pressed while the display is
flashing, will stop the flashing, and perform the
requested function.
TIP
You may press and hold the UP ARROW or
DOWN ARROW key to quickly change the set-
point. The longer the key is held, the faster the
setting will change.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...