9
2-11
62-11039
f. Supply Air Temperature Sensor (1SAT)
1SAT is a temperature control probe which provides
micro with supply air temperature information to be dis-
played, recorded in the data recorder and used to con-
trol the refrigeration system. It is located on the supply
air grille.
2.5 REMOTE EVAPORATOR(S)
The compartments of the MultiTemp system are
equipped with separate evaporators.
For MultiTemp remote compartment applications single
and dual air discharge evaporators are available. The
evaporators are different in size, capacity and number of
fans, but all work on the same principle and use the
same three-phase 45Hz to 65Hz fan assembly.
The remote evaporator(s) consist of evaporator coil(s),
evaporator fan motor(s), thermostatic expansion
valve(s), defrost termination sensor(s), 12V liquid line
solenoid(s), 12V water drain heater(s), evaporator coil
heaters, return air and optional supply air sensor(s) and
high temperature safeties.
The bottom section of the evaporator allows easy
access to both the electrical and refrigeration hardware.
2.6 SYSTEM OPERATING CONTROLS AND
COMPONENTS
The temperature controller is a Carrier Transicold
Advance Microprocessor controller (Refer to Section
2.6.3 and 3). Once the controller is set at the desired
temperature, the unit will operate automatically to
maintain the desired temperature within very close
limits.
The microprocessor controller consists of two modules
-- the control module and display and keypad module.
The
control
box
includes
manual
switches,
microprocessor, fuses, and associated wiring.
Standard equipment includes an auto start--stop
feature. This feature provides automatic cycling of the
diesel engine, which in turn offers an energy efficient
alternative to continuous operation of the engine with
control of temperature by alternate cooling and heating
of the supply air (evaporator outlet air).
2.6.1 Multiple Languages
Messages in the MessageCenter can be displayed in
English, French or Spanish.
Press and hold = key for 6 seconds to view or change
the current language selection. See Section 3.16 for
more information on functional parameters.
2.6.2 Special Features
The following special features are incorporated into the
Carrier Transicold Advance Microprocessor:
A MessageCenter which clearly displays all information
in dot matrix form.
Unit Operation & Alarms are displayed in English (not in
codes)
UltraFresh 3
Large LCD Display
Unit Data and Functional Parameters
Programmable Maintenance Hour Meters
PM Hour Meters are resettable from the Keypad
Bright LED Alarm Light
Bright LED Mode Lights
Fully Automated Pretrip
Automated Micro Self--test
Data Recorder
Data Recorder date & time can be set from the Keypad
Auto Start--Stop
Trip Start to record date/time of trip in Data Recorder
memory
PC card functionality for Downloading data, upgrade
programming, and Configuration set up
FETs
(Field Effect
Transistors)
for switching
components on & off, and checking circuit current
Automatic or Manual Engine Starting
Functional Parameter locks
Alarms are stored in microprocessor memory for future
reference
New Menu system to simplify keyboard and enhance
functionality
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...