62-11039
3-26
FUNCTIONAL
PARAMETER
DESCRIPTION
SELECTIONS
SLEEP MODE
NO
YES
NO -- is the normal operating selection.
YES-- selects Sleep Mode. In this mode the unit will operate only as
needed to keep the engine warm, and the battery charged. There is
NO TEMPERATURE CONTROL in Sleep Mode.
* OVERRIDE
DOOR
SHUTDOWN
Two compartment
only
NO
YES
NO -- allows the door switch to shut the unit down whenever the refrig-
erated compartment door is opened and the door switch is configured
for shutdown.
YES -- allows you to override the refrigerated compartment door shut-
down switch, and allow the unit to continue to run, even with the refrig-
erated compartment door open.
* NO POWER --
SWITCH TO
DIESEL
NO
YES
NO -- Will override switch to engine configuration and shut down unit
when electric standby power is lost.
YES -- Will shut down unit when standby power is lost.
LANGUAGE /
IDIOMAS:
LANGUE:
ENGLISH
ESPAÑOL
FRANÇAIS
ENGLISH
-- All information displayed in the MessageCenter will be
shown in English.
FRANÇAIS-- All information displayed in the MessageCenter will be
shown in French.
ESPAÑOL-- All information displayed in the MessageCenter will be
shown in Spanish.
NOTE:
This parameter can be quickly accessed by pressing and hold-
ing the Select Key for 6 seconds.
Selections in
BOLD
are the default settings.
* This Functional Parameter may not appear in the list for your unit, depending on how the microprocessor has been configured.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...