62-11039
6-3
MessageCenter MESSAGES
Message
Description
KEYPAD LOCKED--BATTERY TOO LOW
If any keys are pressed while “UNIT BATTERY--xx V” message is
being displayed this message will be displayed as a warning that no
changes can be made and information can not be viewed until the
battery voltage is brought back up above 10 volts for more than 10
seconds.
LOADING INFO
A Configuration PC Card has been inserted into the PC Card slot,
and information from the Config card is being loaded into the Micro.
DO NOT REMOVE THE CARD WHILE THIS MESSAGE IS BE-
ING DISPLAYED.
MAIN MENU
Consists of Configuration Mode, Component Test and Service
Modes.
MAX SETPOINT HAS BEEN REACHED
Maximum setpoint allowed by configuration settings has been
reached.
MICRO WILL STOP IN XXX SECONDS
The RS has been turned OFF and the system valves are closing.
The display will turn off when the count down reaches zero.
MIN SETPOINT HAS BEEN REACHED
Minimum setpoint defined by functional parameters has been
reached.
NEW SW: = TO LOAD, TO
↑
CANCEL
A Program PC Card has been inserted into the PC Card slot, and
the program on the PC Card is a newer version than what is al-
ready loaded in the Micro. Press = to load the program.
NO ACTION TAKEN, REMOVE CARD
A Program PC Card has been inserted into the PC Card slot, and
no key presses have been made to install the program into the Mi-
cro. The PC Card may be safely removed from the slot.
NO ACTIVE ALARMS
There are no active alarms in the Micro Alarm List.
NO DATA ON CARD, REMOVE CARD
A Program or Configuration PC Card has been inserted into the PC
Card slot, and no valid data is present on the PC Card. The PC
Card may safely be removed from the unit.
NO DATA TO COPY, REMOVE CARD
A Download PC Card has been inserted into the PC Card slot, and
there is no valid data in the Data Recorder to copy onto the PC
Card. The PC Card may safely be removed from the unit.
NO INACTIVE ALARMS
There are no inactive alarms in the Alarm List
NO INSTALLS LEFT, REMOVE CARD
An Option PC Card has been inserted into the PC Card slot, and all
install options have been used. The PC Card may safely be re-
moved from the unit.
OLD INTELLISETS--USE REEFERMAN
A Program PC Card has been inserted into the PC Card slot and
the unit model type on the card is not within the same unit family as
the controller model type
OLD SW:CANNOT LOAD--REMOVE
CARD
A Program PC Card has been inserted into the PC Card slot, and
the program on the PC Card is a much older version that can not
be loaded in the Micro.
OLD SW, = TO LOAD,
↑
TO CANCEL
A Program PC Card has been inserted into the PC Card slot, and
the program on the PC Card is an older version than what is al-
ready loaded in the Micro. Press = to load the older program.
PC MODE
Start/Run--Off Switch is OFF, the PC Mode Jumper is connected
and engine is not running in order to enter PC Mode. PC Mode al-
lows the user to access and download data using a computer when
the unit is not running and without starting the 8 hour data recorder
timer. Refer to Section 5.1.
PM DUE
Preventative Maintenance is now due on the unit.
PRESS
↑↓
TO VIEW DATA
Press the up or down arrow key to scroll through the Data List.
PRESS
↑↓
TO VIEW SETTINGS
Press the up or down arrow key to scroll through Functional Pa-
rameter Settings
PRESS
↑↓
TO VIEW PRINT MENU
Press the up or down arrow key to view the Strip Print setup menu.
PRESS = TO MARK TRIP START
Press the = key to mark the start of the trip in the Data Recorder.
PRESS = TO START PRETRIP
Press the = key to begin pretrip tests.
PRETRIP FAIL & COMPLETED
Some of the pretrip tests did not pass.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...