d. ProductShield: Winter
When the unit is set for Start/Stop operation,
ProductShield Winter allows it to switch to continuous
run when the ambient temperature falls below a
pre--programmed temperature. This will protect the unit
from the complication of fuel gelling.
Once the micro detects that the ambient temperature
has dropped below the pre--programmed temperature,
the unit will switch from auto Start/Stop to Continuous
Run. The unit will continue to operate in Continuous Run
for a minimum of 30 minutes. After 30 minutes, the unit
will return to auto Start/Stop once the ambient
temperature has risen more than 3.6
°
F (2
°
C) above the
pre--programmed ProductShield Winter temperature.
All of the ProductShield settings are in the Data List
(Refer to Section 3.14). The Data List will reflect the
ProductShield settings for the IntelliSet commodity that
is currently active.
NOTE
ProductShield does not operate within Sleep
Mode.
4.6.2 Temperature Ranges
Each ProductShield setting allows the user to select a
ambient temperature range in which to operate.
The Minimum and Maximum range values can be set to
OFF, or any value from --19
°
F to +119
°
F (--28.3
°
C to
+48.3
°
C ).
The examples below all use the same settings and
illustrate the differences in unit operation for the various
ProductShield selections.
a. ProductShield: Econo: Go To Start/Stop
Examples
The following examples apply in situations where all
other Start/Stop conditions have been met.
If the Minimum is set to 30
°
F (--1.1
°
C) and the Maximum
is set to 42
°
F (5.6
°
C) and the
ambient air
temperature
falls
between
these temperatures, the unit operation
can change to Econo Start/Stop.
If the Minimum is set to OFF and the Maximum is set to
35
°
F (1.7
°
C) and the
ambient air
temperature falls
below
35
°
F (1.7
°
C), the unit operation can change to
Econo Start/Stop.
If the Minimum is set to 70
°
F (21.1
°
) and the Maximum is
set to OFF and the
ambient air
temperature is
above
70
°
F (1.7
°
C), the unit operation can change to Econo
Start/Stop.
b. ProductShield: Econo: Go To Continuous Run
Examples
If the Minimum is set to 30
°
F (--1.1
°
C) and the Maximum
is set to 42
°
F (5.6
°
C) and the
ambient air
temperature
falls
outside
these temperatures, the unit operation will
change to Econo Continuous Run.
If the Minimum is set to OFF and the Maximum is set to
35
°
F (1.7
°
C) and the
ambient air
temperature falls
above
35
°
F (1.7
°
C), the unit operation will change to
Econo Continuous Run.
If the Minimum is set to 70
°
F (21.1
°
) and the Maximum is
set to OFF and the
ambient air
temperature is
below
70
°
F (1.7
°
C), the unit operation will change to Econo
Continuous Run.
c. ProductShield: High Air Examples
If the Minimum is set to 15
°
F (--9.4
°
C) and the Maximum
is set to 85
°
F (29.4
°
C) and the
ambient air
temperature
falls
outside
these temperatures, the unit operation will
change to Econo High Air.
If the Minimum is set to OFF and the Maximum is set to
35
°
F (1.7
°
C) and the
ambient air
temperature falls
above
35
°
F (1.7
°
C), the unit operation will change to
Econo High Air.
If the Minimum is set to 70
°
F (21.1
°
) and the Maximum is
set to OFF and the
ambient air
temperature is
below
70
°
F (1.7
°
C), the unit operation will change to Econo
High Air.
Содержание VECTOR 1800 MT
Страница 1: ......
Страница 2: ...OPERATION SERVICE MANUAL for VECTOR 1800 MT Trailer Multi Temp Refrigeration Units ...
Страница 19: ...1 5 62 11039 1 3 SAFETY DECALS ...
Страница 20: ...1 6 62 11039 62 03958 00 Heat Warning 62 03957 01 High Voltage 62 60280 00 Standby Safety ...
Страница 21: ...1 7 62 11039 ...
Страница 303: ...10 1 62 11039 ...
Страница 310: ...10 8 62 11039 BASED ON ENGINEERING SCHEMATIC 62 60926 REV G NEXT SHT ...
Страница 311: ...10 9 62 11039 FROM PREVIOUS SHT ...