Operation using the data setting device
Azbil Corporation
6-38
Model MTG11A/18A, MTG11B/18B, MTG14C
Printing example
The following shows an example of an actual configuration printout accompanied by
line-by-line descriptions.
Printing example
Meaning
‘02-01-01 00:00
TAG No. XXXXXXXX
Detector
DIA
: 50 A
TYPE
: MGG
EX
: 300.0 mA
RANGE
: SINGLE
ANA/DE : ANALOG XMTR
D1
: D1 NOT USED
DO
: DO NOT USED
SW VER : 3.1
DAMP
: 3.00
SPAN1
: 70.69 m3
GRAVITY : 1.0000
COEFF
: 1.0000
LOFCUT : ON
0.6 %
F/S I
: UP
DO
: OPEN
P
: HOLD
PULSE
CONF
: ADD
RESET
: 0000000000
WEIGHT : 110 cc/p
WIDTH
: DUTY 50%
DROP
: 0.5%
INPUT
: 70.69 m3
OUTPUT : 100.02 %
STATUS CHECK= OK
Time when printed
Tag no.
Detector information
Diameter
Type
Detector constant
Range
Communication mode
Setting of contact input
Setting of contact output
Software version
Damping constant
Span
Specific gravity
Correction coefficient
Low flow cutoff
Burnout (4-20 mA output)
Burnout (Contact output)
Burnout (Pulse output)
Pulse information
Setting of built-in counter
Reset value
Pulse scale
Pulse width
Dropout value
Input value
Output value
Status
CM2-MTG300-2001.book 38 ページ 2015年9月29日 火曜日 午前10時14分
Содержание MagneW Neo PLUS
Страница 16: ...List of Figures Tables CM2 MTG300 2001 book 4...
Страница 92: ...MEMO CM2 MTG300 2001 book 38...
Страница 106: ...MEMO CM2 MTG300 2001 book 4...
Страница 266: ...MEMO CM2 MTG300 2001 book 82...
Страница 312: ...MEMO CM2 MTG300 2001 book 46...
Страница 336: ...MEMO CM2 MTG300 2001 book 22...
Страница 338: ...CM2 MTG300 2001 book 2...