Maintenance and troubleshooting
Azbil Corporation
8-4
Model MTG11A/18A, MTG11B/18B, MTG14C
.
Figure 8-4
Figure 8-5
Fuse may blow.
Remove the XY cable from the connector CN2. (Fig.8-4)
Measure the resistance between No. 1 pin of CN2 and
CP20. (Fig.8-5)
Fuse is not broken.
Check and look for the other causes for the problem.
Resistance: Greater than 500
Ω
Yes
No
CN2
XY cable
CP20(yellow check pin)
No.1 pin of CN2
(right side pin)