Azbil Corporation
Operation using the data setting device
Model MTG11A/18A, MTG11B/18B, MTG14C
5-37
The procedure for entering MAINTENANCE MODE is shown below.
Step
Procedure
Screen
1
The screen shown on the right is a screen display
example in MEASURING MODE (measurement
state).
Press the MODE key.
2
The OPERATOR'S MODE screen appears for
approx. two seconds and then the damping setting
screen appears.
3
Press the key once to display the screen as
shown on the right.
4
Press the key once to move the cursor to the
position shown on the screen.
5
Press the key.
With the display changed, MAINTENANCE
MODE is active.
The screen appears in approx. two seconds.
20.0 %
01.94 m
3
/h
WP0
00069401
20.0 %
* OPERATOR'S
MODE
20.0 %
* DAMPING
005.0 s
20.0 %
* MODE ENTER
MAINTENANCE
20.0 %
* MODE ENTER
MAINTENANCE
20.0 %
> MAINTENANCE
MODE
20.0 %
> OUTPUT CHECK
MODE
OFF
CM2-MTG300-2001.book 37 ページ 2015年9月29日 火曜日 午前10時14分