Chapter 4: Managing Units
123
Properties
on page 115. (When changing an IP address, always change it in the Appliance
Network Settings window before changing it in the Unit Network Properties window.)
•
Type a subnet, in standard dot notation (xxx.xxx.xxx.xxx).
•
Type a gateway, in standard dot notation (xxx.xxx.xxx.xxx).
•
Specify a LAN speed. This network setting will not appear for CPS appliances.
•
Enable or disable DHCP or BootP (DS1800 digital switches and DSR switches).
•
Enable or disable ICMP ping reply.
3.
Click
Save
and then click
Close
. The Units View window will open.
To change the IP addresses of DSView 3 software servers used for managed
appliance authentication:
1.
In a Units View window containing appliances (see
Accessing Units View windows
on
page 88), click on the appliance name.
2.
Click
Appliance Settings
in the side navigation bar and then click
Authentication Servers
. The
Appliance Authentication Servers Settings window will open. To change information, type an
IP address, in standard dot notation (xxx.xxx.xxx.xxx), for up to four DSView 3 software
servers the managed appliance will use for authentication.
3.
Click
Save
and then click
Close
. The Units View window will open.
To display version information for one or more managed appliances from a Units
View window:
1.
In a Units View window containing appliances (see
Accessing Units View windows
on
page 88), click the checkbox next to the unit(s). To display information about all units in the
page, click the checkbox to the left of Name at the top of the list.
2.
Click
Operations
, then select
Show Versions
from the drop-down menu.
3.
A Multiple Unit Operation window will open, containing a link to view results; see
Multiple
unit operations from a Units View window
on page 92.
The results window includes the unit name, type and when the version information
retrieval began.
The Appliance Version field will contain the main firmware version; if a unit did not or cannot
report a firmware version, dashes are displayed.
The Boot Version field contains the boot firmware version. If a unit does not support a boot
version but has an appliance version, N/A will be displayed. Dashes will be displayed if a unit
does not support either appliance or boot firmware.
The Status field indicates the result of the display (for example, Show Versions complete or
Show Versions not supported).
To display version information for a managed appliance:
1.
In a Units View window containing appliances (see
Accessing Units View windows
on
page 88), click on an appliance name.
Содержание DSView 3
Страница 1: ...Installer User Guide DSView 3...
Страница 2: ......
Страница 4: ......
Страница 16: ...xiv DSView 3 Software Installer User Guide...
Страница 54: ...36 DSView 3 Software Installer User Guide...
Страница 66: ...48 DSView 3 Software Installer User Guide...
Страница 196: ...178 DSView 3 Software Installer User Guide...
Страница 266: ...248 DSView 3 Software Installer User Guide...
Страница 282: ...264 DSView 3 Software Installer User Guide...
Страница 320: ...302 DSView 3 Software Installer User Guide...
Страница 326: ...308 DSView 3 Software Installer User Guide...
Страница 372: ...354 DSView 3 Software Installer User Guide...
Страница 383: ......