DRV-28 inverter
s Basic operartion instructions
-75-
Function
code
Name
Detailed parameter description
Default
value
asynchronous motor 1
on model
P02.06
Stator resistance of
asynchronous motor 1
0.001–65.535Ω
Depend
on model
P02.07
Rotor resistance of
asynchronous motor 1
0.001–65.535Ω
Depend
on model
P02.08
Leakage inductance of
asynchronous motor 1
0.1–6553.5mH
Depend
on model
P02.09
Mutual inductance of
asynchronous motor 1
0.1–6553.5mH
Depend
on model
P02.10
No-load current of
asynchronous motor 1
0.1–6553.5A
Depend
on model
P02.15
Rated power of synchronous
motor 1
0.1–3000.0kW
Depend
on model
P02.16
Rated frequency of
synchronous motor 1
0.01Hz–P00.03 (Max. output frequency)
50.00Hz
P02.17
Number of pole pairs of
synchronous motor 1
1–50
2
P02.18
Rated voltage of
synchronous motor 1
0–1200V
Depend
on model
P02.19
Rated current of
synchronous motor 1
0.8–6000.0A
Depend
on model
P02.20
Stator resistance of
synchronous motor 1
0.001–65.535Ω
Depend
on model
P02.21
Direct-axis inductance of
synchronous motor 1
0.01–655.35mH
Depend
on model
P02.22
Quadrature-axis inductance
of synchronous motor 1
0.01–655.35mH
Depend
on model
P02.23
Counter-emf constant of
synchronous motor 1
0–10000
300
P05.01–
P05.06
Function of multi-function
digital input terminal (S1–S4,
HDIA,HDIB)
35: Motor 1 switches to motor 2
/
P08.31
Switching between motor 1
and motor 2
0x00–0x14
Ones: Switch-over channel
0: Switch over by terminal
1: Switch over by MODBUS
communication
2: Switch over by PROFIBUS / CANopen
00