DRV-28 inverter
s Function parameter list
-181-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P10.03
Running time of
0
th
step
are -100.0–100.0%, 100% corresponds to Max.
output frequency P00.03.
Setting range of the running time in 0
th
–15
th
sections
are 0.0–6553.5s (min), the time unit is determined by
P10.37.
When simple PLC operation is selected, it is required
to set P10.02–P10.33 to determine the running
frequency and running time of each section.
Note: The symbol of multi-step speed
determines the running direction of simple PLC,
and the negative value means reverse running.
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
Deceleration time
(two sections)
Acceleration time
(two sections)
P10.03
P10.05
P10.07
P10.31
P10.33
When selecting multi-step speed running, the
multi-step speed is within the range of -fmax–fmax,
and it can be set continuously. The start/stop of
multi-step stop is also determined by P00.01.
DRV-28 series inverter can set 16-step speed, which
are set by combined codes of multi-step terminals 1–
4 (set by S terminal, correspond to function code
P05.01–P05.06) and correspond to multi-step speed
0 to multi-step speed 15.
Output frequency
t
t
t
t
t
terminal 1
terminal 2
terminal 3
terminal 4
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
When terminal 1, terminal 2, terminal 3 and terminal
4 are OFF, the frequency input mode is set by
P00.06 or P00.07. When terminal 1, terminal 2,
0.0s(min)
○
P10.04 Multi-step speed 1
0.0%
○
P10.05
Running time of
1
st
step
0.0s(min)
○
P10.06 Multi-step speed 2
0.0%
○
P10.07
Running time of
2
nd
step
0.0s(min)
○
P10.08 Multi-step speed 3
0.0%
○
P10.09
Running time of
3
rd
step
0.0s(min)
○
P10.10 Multi-step speed 4
0.0%
○
P10.11
Running time of
4
th
step
0.0s(min)
○
P10.12 Multi-step speed 5
0.0%
○
P10.13
Running time of
5
th
step
0.0s(min)
○
P10.14 Multi-step speed 6
0.0%
○
P10.15
Running time of
6
th
step
0.0s(min)
○
P10.16 Multi-step speed 7
0.0%
○
P10.17
Running time of
7
th
step
0.0s(min)
○
P10.18 Multi-step speed 8
0.0%
○
P10.19
Running time of
8
th
step
0.0s(min)
○
P10.20 Multi-step speed 9
0.0%
○
P10.21
Running time of
9
th
step
0.0s(min)
○
P10.22
Multi-step speed
10
0.0%
○
P10.23
Running time of
10
th
step
0.0s(min)
○
P10.24
Multi-step speed
11
0.0%
○
P10.25 Running time of
0.0s(min)
○