DRV-28 inverter
s Function parameter list
-155-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
57: Motor over-temperature fault input
58: Enable rigid tapping
59: Switches to V/F control
60: Switches to FVC control
61: PID polarity switch-over
62: Reserved
63: Enable servo
64: Limit of forward run
65: Limit of reverse run
66: Zero out encoder counting
67: Pulse increase
68: Enable pulse superimposition
69: Pulse decrease
70: Electronic gear selection
71–79: Reserved
P05.07
Reserved
variables
0–65535
0
●
P05.08
Polarity of input
terminal
This function code is used to set the polarity of input
terminals.
When the bit is set to 0, input terminal polarity is
positive;
When the bit is set to 1, input terminal polarity is
negative;
0x000–0x3F
0x000
○
P05.09 Digital filter time
Set S1
–S4, filter time of HDI terminal sampling. In
cases where interference is strong, increase the
value of this parameter to avoid mal-operation.
0.000
–1.000s
0.010s
○
P05.10
Virtual terminal
setting
0x000–0x3F (0: disable, 1: enable)
BIT0: S1 virtual terminal
BIT1: S2 virtual terminal
BIT2: S3 virtual terminal
BIT3: S4 virtual terminal
BIT4: HDIA virtual terminal
BIT5: HDIB virtual terminal
0x00
◎
P05.11
2/3 Wire control
mode
This function code is used to set the 2/3 Wire control
mode.
0: 2-Wire control 1; integrate enabling function with
direction. This mode is the most popular dual-line
0
◎