DRV-28 inverter
s Function parameter list
-153-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
disabled.
Setting range: 0.00
–20.00 Hz
P04.50
Reserved
variable
0
–65535
0
●
P04.51
Reserved
variable
0
–65535
0
●
P05 group Input terminals
P05.00
HDI input type
0x00–0x11
Ones: HDIA input type
0: HDIA is high-speed pulse input
1: HDIA is digital input
Tens: HDIB input type
0: HDIB is high-speed pulse input
1: HDIB is digital input
0
◎
P05.01
Function of S1
terminal
0: No function
1: Forward running
2: Reverse running
3: 3-wire control/Sin
4: Forward jogging
5: Reverse jogging
6: Coast to stop
7: Fault reset
8: Running pause
9: External fault input
10: Frequency increase (UP)
11: Frequency decrease (DOWN)
12: Clear frequency increase/decrease setting
13: Switch-over between setup A and setup B
14: Switch-over between combination setup and
setup A
15: Switch-over between combination setup and
setup B
16: Multi-step speed terminal 1
17: Multi-step speed terminal 2
18: Multi-step speed terminal 3
19: Multi-step speed terminal 4
20: Multi-step speed pause
21: Acceleration/deceleration time selection 1
22: Acceleration/deceleration time selection 2
1
◎
P05.02
Function of S2
terminal
4
◎
P05.03
Function of S3
terminal
7
◎
P05.04
Function of S4
terminal
0
◎
P05.05
Function of HDIA
terminal
0
◎
P05.06
Function of HDIB
terminal
0
◎