DRV-28 inverter
s Function parameter list
-166-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
selection of
STOP/RST key
For fault reset, STOP/RST is valid under any
situation.
0: valid only for panel control only
1: valid for both panel and terminal control
2: valid for both panel and communication control
3: valid for all control modes
P07.05–
P07.07
Reserved variables
/
/
P07.08
Frequency
display
coefficient
0.01–10.00
Display frequency=running frequency× P07.08
1.00
○
P07.09
Speed display
coefficient
0.1–999.9%
Mechanical speed=120×display running
frequency×P07.09/number of motor pole pairs
100.0%
○
P07.10
Linear speed
display
coefficient
0.1–999.9%
Linear speed=mechanical speed×P07.10
1.0%
○
P07.11
Temperature of
rectifier bridge
module
-
20.0–120.0°C
/
●
P07.12
Temperature of
inverter module
-
20.0–120.0°C
/
●
P07.13
Software version
of control board
1.00–655.35
/
●
P07.14
Accumulated
running time
0–65535h
/
●
P07.15
High bit of
inverter power
consumption
Display the power consumption of the inverter.
Inverter power consumption=P07.15
×1000+P07.16
Setting range of P07.15: 0
–65535 kWh (×1000)
Setting range of P07.16: 0.0–999.9 kWh
/
●
P07.16
Low bit of inverter
power
consumption
/
●
P07.17 Reserved
/
/
P07.18
Rated power of
inverter
0.4–3000.0kW
/
●
P07.19
Rated voltage of
inverter
50–1200V
/
●
P07.20 Rated current of 0.1–6000.0A
/
●